
Add to Cart
Super Mini uni-tube blown cable
Quick Details:
Blown cable has four components: 1) microduct, 2) the blowing apparatus, 3) the optical-fiber bundles, and 4) the connecting/terminating hardware. The microduct consists of multiple individual tubes, bundled into a single sheath. The fiber packages or units are designed to be blown into preplaced tubes using a compressed-gas system. Tubes are connected by splices and connectors that route the fibers from one continuous pipe to the next. On the ends of each run, the tubes require fittings.
Features and Benefits
Special complex material loose tube, reduce the shrink of tube in cold temperature.
Accurate fibre length balance, stable mechanical and temperature performance.
Particular technique control, prevent sheath form crinkling during installation.
Structure Innovation in sheath, enhancing the blowing performance.
Standards
Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications.
Optical fibre …..ITU-T G.652D,G657,IEC 60793-2-50 Optical cable ….IEC 60794-5,IEC 60794-1-2
Technical Index
Cable Type | GCYFXTY-XB1.3(MTE + Cable diameter) | |||
MTE2.0 | MTE2.3 | MTE2.8 | ||
Fibre Count | 2~4 | 6~12 | 14~24 | |
Thickness of HDPE sheath | Nominal value:0.20mm, | |||
Nominal Overall Diameter | 2.0±0.1mm | 2.3±0.1mm | 2.8±0.1mm | |
Weight | 4.0 kg/km | 5.0 kg/km | 7.0kg/km | |
Cable Fibre Attenuation (single mode) | 0.35dB/km max @1310nm 0.22dB/km max @1550nm | |||
Max. Tensile Strength | 40N | 50N | 60N | |
Max. Crushing force | 600N/100mm | |||
Min. Bending radius -Static / Dynamic | 10 / 20 outer Φ | |||
Temperature | Storage -30~+50℃;Installation-10~+40℃;Operation-20~+50℃ | |||
Cable service life (estimate value) | 25 years |
Testing Index
Blowing performance
Blowing Tool | Typical blowing length | ||
PLUMETTAZ:PR-140, MiniJet-400 etc. | Fibres Count | Duct type 3.5/5.0mm | Duct type 5.5/7.0mm |
Air pressure : 13bar | 2~12 fibres | 800m | 1500m |
14~24 fibres | 500m | 1500m | |
Mechanic performance
Item | Testing Method | Testing Results | Specified Value | |
Tension performance | IEC 60794-1-2-E1 | Optical fibre strain | Additional attenuation | Max. Tensile Strength =Short term Allowable tension ≈2×(Long term Allowable Tension) |
Short term:≤0.3% Long term:≤0.1% | Short term: Da <0.1 dB,Da reversible; Long term: Da ≤0.03 dB | |||
Crush | IEC 60794-1-2-E3 | Short term: Da <0.10 dB, Da reversible; Long term: Da ≤0.03 dB; The outer sheath has no visible crack. | Short term crushing force =600 N Long term crushing force =300 N | |
Repeated Bending | IEC 60794-1-2-E6 | After test, Da ≤0.03 dB; The outer sheath has no visible crack. | R=20 outer Φ | |
Bending load =15N | ||||
Bending times =25 | ||||
Torsion | IEC 60794-1-2-E7 | After test, Da ≤0.03 dB; The outer sheath has no visible crack. | Torsion angle=±180º | |
Torsion load =15N | ||||
Torsion times =5 | ||||
Cable bend | IEC 60794-1-2-E11A | After test, The optical fibre can’t be broken; The outer sheath has no visible crack. | R=20 outer Φ | |
10Turns | ||||
Cycles times =5 |
Environment performance
Item | Testing Method | Testing Results | ||
Temperature cycling | IEC 60794-1-2-F1 | Allowable additional attenuation (1550nm) | ||
G.652B | G652D | G.657 | ||
Da ≤0.10 dB/km, Da reversible; | ||||
Water penetration | IEC 60794-1-2-F5B | Water column: 1m, 3m cable, Period:24 hours No water leak through the open end of cable | ||
Filling compound flow | IEC 60794-1-2-E14 | 70℃,Period:24 hours No compound flow from the cable | ||