Features and Benefits
Standards
Basic Performance Testing parameter
Fibre Unit Attenuation
Fibre Type | SM G.652D,G.657 |
Attenuation | 0.40dB/km max @1310nm |
0.30dB/km max @1550nm | |
Blowing Test
Fibre Count | 2 Fibres | 4 Fibres | 6 Fibres | 8 Fibres | 12 Fibres | ||
Test equipment | PLUMETTAZ:UM25, | ERICSSON:F, | CATWAY:FBT-1.1 | ||||
Standard duct | 5.0/3.5 mm | ||||||
Pressure | 7bar / 10bar | ||||||
Typical blowing distance | 500m / 1000 m | 500m / 1000m | 500m / 1000m | 500m / 1000m | 500m / 800m | ||
Typical blowing time | 10 min / 18 min | 10 min / 18 min | 12 min / 18 min | 13 min / 18 min | 15 min / 20 min |
Mechanical Performance
Test | Standard | Parameters | Test Results | |
Tension | EN 18700 A1/501 | Load is 1×W | Additional attenuation ≤0.05dB after test | |
IEC 60794-1-2-E1 | ||||
Bend | IEC 60794-1-2–E11A | Diam 40mm×3turns | Additional attenuation ≤0.05dB,after test | |
5 cycles at 20℃ | ||||
Crush | IEC 60794-1-2-E3 | 100 N, 60s | Additional attenuation ≤0.05dB,after test | |
Environment Performance
Test | Standard | Parameters | Test Results | |
Temperature Cycle | IEC 60794-1-2-F1 | -30°C, +70°C, | Absolute attenuation ≤0.5dB/km, during test | |
(2 cycles) | Additional attenuation ≤0.1dB/km, during and after test | |||
Water Soak | IEC 60794-5 | 1000 hours in water, | (Test after temp cycle) ≤0.07dB/km | |
18℃~22℃ | Change compared to start value | |||
Damp Heat Cycle | IEC 60068-2-38 | 25°C, 65°C, 25°C, 65°C, | Absolute attenuation ≤0.5dB/km, during test | |
25°C,-10°C, 25°C | Additional attenuation ≤0.1dB/km, during and after test | |||